PDP, SSV, and CFV molar flow rate calculations.

§ 1065.642 PDP, SSV, and CFV molar flow rate calculations.

This section describes the equations for calculating molar flow rates from various flow meters. After you calibrate a flow meter according to § 1065.640, use the calculations described in this section to calculate flow during an emission test.

(a) PDP molar flow rate. (1) Based on the speed at which you operate the PDP for a test interval, select the corresponding slope, a1, and intercept, a0, as calculated in § 1065.640, to calculate PDP molar flow rate,, as follows:

er25oc16.185.gif

Where:

fnPDP = pump speed. Vrev = PDP volume pumped per revolution, as determined in paragraph (a)(2) of this section. pin = static absolute pressure at the PDP inlet. R = molar gas constant. Tin = absolute temperature at the PDP inlet.

(2) Calculate Vrev using the following equation:

er25oc16.186.gif
pout = static absolute pressure at the PDP outlet.

Example:

a1 = 0.8405 (m /s) fnPDP = 12.58 r/s Pout = 99.950 kPa Pin = 98.575 kPa = 98575 Pa = 98575 kg/(m·s ) a0 = 0.056 (m /r) R = 8.314472 J/(mol·K) = 8.314472 (m ·kg)/(s ·mol·K) Tin = 323.5 K
er25oc16.187.gif
er25oc16.188.gif
n = 29.428 mol/s