Required experimental conditions for the validation study and subsequent use during decontamination.

§ 761.386 Required experimental conditions for the validation study and subsequent use during decontamination.

The following experimental conditions apply for any solvent:

(a) Temperature and pressure. Conduct the validation study and perform decontamination at room temperature (from ≥15 °C to ≤30 °C) and at atmospheric pressure.

(b) Agitation. Limit the movement in the solvent to the short-term movement from placing the contaminated surface into the soak solvent and from removing the surface from the soak solvent.

(c) Time of soak. Soak the surface for a minimum of 1 hour.

This document is only available to subscribers. Please log in or purchase access.