Pretreatment standards for existing sources.

§ 467.15 Pretreatment standards for existing sources.

Except as provided in 40 CFR 403.7 and 403.13, any existing source subject to this subpart which introduces pollutants into a publicly owned treatment works must comply with 40 CFR part 403 and achieve the following pretreatment standards for existing sources. The mass of wastewater pollutants in aluminum forming process wastewater introduced into a POTW shall not exceed the following values:

Subpart A

Core With an Annealing Furnace Scrubber

Pollutant or pollutant property PSES
Maximum for any 1 day Maximum for monthly average
mg/off-kg (lb/million off-lbs) of aluminum rolled with neat oils
Chromium0.0360.015
Cyanide0.0240.010
Zinc0.1190.050
TTO0.057
Oil and grease (alternate monitoring parameter)4.32.1
This document is only available to subscribers. Please log in or purchase access.