Monitoring and QA/QC requirements.

§ 98.414 Monitoring and QA/QC requirements.

(a) The mass of fluorinated GHGs, fluorinated HTFs, or nitrous oxide coming out of the production process shall be measured using flowmeters, weigh scales, or a combination of volumetric and density measurements with an accuracy and precision of one percent of full scale or better. If the measured mass includes more than one fluorinated GHG or fluorinated HTF, the concentrations of each of the fluorinated GHGs or fluorinated HTFs, other than low-concentration constituents, shall be measured as set forth in paragraph (n) of this section. For each fluorinated GHG or fluorinated HTF, the mean of the concentrations of that fluorinated GHG (mass fraction) measured under paragraph (n) shall be multiplied by the mass measurement to obtain the mass of that fluorinated GHG or fluorinated HTF coming out of the production process.

(b) The mass of any used fluorinated GHGs, fluorinated HTFs, or used nitrous oxide added back into the production process upstream of the output measurement in paragraph (a) of this section shall be measured using flowmeters, weigh scales, or a combination of volumetric and density measurements with an accuracy and precision of one percent of full scale or better. If the mass in paragraph (a) is measured by weighing containers that include returned heels as well as newly produced fluorinated GHGs or fluorinated HTFs, the returned heels shall be considered used fluorinated GHGs or fluorinated HTFs for purposes of this paragraph (b) and § 98.413(b).

(c) The mass of fluorinated GHGs, fluorinated HTFs, or nitrous oxide fed into the transformation process shall be measured using flowmeters, weigh scales, or a combination of volumetric and density measurements with an accuracy and precision of one percent of full scale or better.

(d) The fraction of the fluorinated GHGs, fluorinated HTFs, or nitrous oxide fed into the transformation process that is actually transformed shall be estimated considering yield calculations or quantities of unreacted fluorinated GHGs, fluorinated HTFs, or nitrous oxide permanently removed from the process and recovered, destroyed, or emitted.

(e) The mass of fluorinated GHGs, fluorinated HTFs, or nitrous oxide sent to another facility for transformation shall be measured using flowmeters, weigh scales, or a combination of volumetric and density measurements with an accuracy and precision of one percent of full scale or better.