General requirements.

§ 97.70 General requirements.

The owners and operators, and to the extent applicable, the NOX authorized account representative of a NOX Budget unit, shall comply with the monitoring, recordkeeping, and reporting requirements as provided in this subpart and in subpart H of part 75 of this chapter. For purposes of complying with such requirements, the definitions in § 97.2 and in § 72.2 of this chapter shall apply, and the terms “affected unit,” “designated representative,” and “continuous emission monitoring system” (or “CEMS”) in part 75 of this chapter shall be deemed to refer to the terms “NOX Budget unit,” “NOX authorized account representative,” and “continuous emission monitoring system” (or “CEMS”) respectively, as defined in § 97.2. The owner or operator of a unit that is not a NOX Budget unit but that is monitored under § 75.72(b)(2)(ii) of this chapter shall comply with the monitoring, recordkeeping, and reporting requirements for a NOX Budget unit under this part.

(a) Requirements for installation, certification, and data accounting. The owner or operator of each NOX Budget unit shall meet the following requirements. These provisions shall also apply to a unit for which an application for a NOX Budget opt-in permit is submitted and not denied or withdrawn, as provided in subpart I of this part:

(1) Install all monitoring systems required under this subpart for monitoring NOX mass emissions. This includes all systems required to monitor NOX emission rate, NOX concentration, heat input rate, and stack flow rate, in accordance with §§ 75.71 and 75.72 of this chapter.

(2) Install all monitoring systems for monitoring heat input rate.

(3) Successfully complete all certification tests required under § 97.71 and meet all other requirements of this subpart and part 75 of this chapter applicable to the monitoring systems under paragraphs (a)(1) and (2) of this section.

This document is only available to subscribers. Please log in or purchase access.