Don't show this message again
§ 461.31 Effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT).
(a) Except as provided in 40 CFR 125.30 through 125.32, any existing point source subject to this subpart must achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available:
(1) Subpart C—Closed Formation—Double Fill, or Fill and Dump.
BPT Effluent Limitations
Pollutant or pollutant property | Maximum for any 1 day | Maximum for monthly average |
---|---|---|
Metric units—mg/kg of lead used | ||
English units—pounds per 1,000,000 pounds of lead used | ||
Copper | 0.86 | 0.45 |
Lead | 0.19 | 0.090 |
Iron | 0.54 | 0.27 |
Oil and grease | 9.00 | 5.40 |
TSS | 18.45 | 8.78 |
pH | ( 1) | ( 1) |
1 Within the range of 7.5 to 10.0 at all times.
(2) Subpart C—Open Formation—Dehydrated.
BPT Effluent Limitations
Pollutant or pollutant property | Maximum for any 1 day | Maximum for monthly average |
---|---|---|
Metric units—mg/kg of lead used | ||
English units—pounds per 1,000,000 pounds of lead used | ||
Copper | 20.99 | 11.05 |
Lead | 4.64 | 2.21 |
Iron | 16.13 | 6.74 |
Oil and grease | 221.00 | 132.60 |
TSS | 453.05 | 215.47 |
pH | ( 1) | ( 1) |