Effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT).

§ 461.11 Effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT).

(a) Except as provided in 40 CFR 125.30 through 125.32, any existing point source subject to this subpart must achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available:

(1) Subpart A—Pasted and Pressed Powder Anodes.

BPT Effluent Limitations

Pollutant or pollutant property Maximum for any 1 day Maximum for monthly average
Metric units—mg/kg of cadmium
English units—pounds per 1,000,000 pounds of cadmium
Cadmium0.920.41
Nickel5.183.43
Zinc3.941.65
Cobalt0.570.24
Oil and grease54.0032.40
TSS111.0052.65
pH( 1)( 1)

1 Within the range of 7.5 to 10.0 at all times.

(2) Subpart A—Electrodeposited Anodes.

BPT Effluent Limitations

Pollutant or pollutant property Maximum for any 1 day Maximum for monthly average
Metric units—mg/kg of cadmium
English units—pounds per 1,000,000 pounds of cadmium
Cadmium237.0104.6
Nickel1,338.2885.2
Zinc1,017.6425.2
Cobalt146.462.7
Oil and grease13,940.08,364.0
TSS28,577.013,592.0
pH( 1)( 1)
This document is only available to subscribers. Please log in or purchase access.