Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT).

§ 419.12 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT).

(a) Except as provided in 40 CFR 125.30 through 125.32, any existing point source subject to this subpart must achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):

Pollutant or pollutant property BPT Effluent Limitations
Maximum for any 1 day Average of daily values for 30 consecutive days shall not exceed
Metric units (kilograms per 1,000 m 3 of feedstock)
BOD522.712.0
TSS15.810.1
COD 1117.060.3
Oil and grease6.93.7
Phenolic compounds0.1680.076
Ammonia as N2.811.27
Sulfide0.1490.068
Total chromium0.3450.20
Hexavalent chromium0.0280.012
pH( 2)( 2)
English units (pounds per 1,000 bbl of feedstock)
BOD58.04.25
TSS5.63.6
COD 141.221.3
Oil and grease2.51.3
Phenolic compounds0.0600.027
Ammonia as N0.990.45
Sulfide0.0530.024
Total chromium0.1220.071
Hexavalent chromium0.010.0044
pH( 2)( 2)

1 See footnote following table in § 419.13(d).

2 Within the range of 6.0 to 9.0.

(b) The limits set forth in paragraph (a) of this section are to be multiplied by the following factors to calculate the maximum for any one day and maximum average of daily values for thirty consecutive days.

This document is only available to subscribers. Please log in or purchase access.